Hotline:   0757-23810755;23810855;23810955;
MR.Huang 13926406303;MR.Yin 13922728266 
   

News

News
Category

Contact us

公司地址
Address: No. 1, Guang long Zhong Road, Guangzhou Long Industrial District, Chen Cun town, Shunde District, Foshan, Guangdong Province, China Tel: 0757-23810755;23810855;23810955 Fax:0757-23810255 Mailbox:88010045@qq.com

Influence the properties of insulating materials

Date: 2017-12-05
Views: 11

development of the construction industry views" (hereinafter referred to as No. 19), third of which clearly put forward to accelerate the implementation of the development of EPC in perfect engineering construction organization mode.

As a general contracting the development of electric power industry experience, advocate, recently, deputy general manager, Chinese Power Construction Group China Electricity

 1. The insulation resistance and resistivity resistance are the reciprocal of the conductance, and the resistivity is the resistance within the unit volume. The smaller the conductive material is, the greater the resistance, the reciprocal relation between the two. For the insulating material, it is always hoped that the resistivity is as high as possible. 

2. The use of the relative dielectric constant and dielectric loss angle tangent insulation material is two: the mutual insulation of the components of the electric network and the medium of the capacitor (energy storage). The former requires a relatively low dielectric constant, which requires a relatively high dielectric constant, and both requirements of dielectric loss tangent is small, especially the application of insulating materials in high frequency and high pressure, the low dielectric loss require insulating material using small dielectric loss tangent. 

3. The breakdown voltage and electrical strength are damaged under a strong electric field, and the insulation property is changed into conductive state, which is called breakdown. The breakdown voltage is called the breakdown voltage (dielectric strength). The electrical strength is the distance between the breakdown voltage and the two electrodes that withstand the applied voltage under the specified conditions, that is the breakdown voltage of the unit thickness. As far as insulating materials are concerned, the higher the value of the breakdown voltage and the electrical strength.

 4. The tensile strength is the maximum tensile stress in the tensile test. It is the most widely used and representative test for the mechanical properties test of insulation materials. 

5. Combustibility refers to the ability of insulation materials to resist burning or to stop burning when they contact flame. With the increasing application of insulating materials, the requirement of its combustion resistance is more important. People can improve and improve the combustion resistance of insulating materials by various means. The higher the combustibility, the better the safety. 

6. Under the prescribed test conditions, the insulating material tolerates the ability of the arc to withstand the arc on its surface. In the test, AC high voltage and small current are used, and the arc action generated by high voltage between the two electrodes is applied to make the time needed to form the conductive layer on the surface of the insulation material, so as to judge the arc resistance of the insulation material. The higher the time value, the better the arc resistance. 

7. The sealing degree is better for the sealing and isolation of oil and water. Yangzhou Kang Sheng insulating material Co., Ltd.


Related news / Recommending More
2017 - 12 - 05
nt present situation as well as how to play the advantages of the general contractor to further promote the development of issues such as an interview with this reporter.Reporter: what do you think is the significance of the introduction of No. 19 to the development of the domestic general contract?Yao qiang:First of all, I want to talk about the document issued 101 "the State Council forward...
2017 - 12 - 05
In November 12th, with the completion of the 10 thousand volt Hou camping line of Liaocheng power supply company in Shandong, it marked the successful completion of the construction target of the coal modification power grid project in Shandong in 2017. Shandong electric power has invested 10 thousand volts and below coal to power matching power grid construction funds, 310 million yuan, new const...
2017 - 12 - 05
Planning Association Yao Qiang No. 19, the introduction of general contract in domestic and foreign developmeThere are many kinds of insulating materials, which can be divided into three categories: gas, liquid and solid. The common gas insulation materials are air, nitrogen, six sulfur fluoride insulating PC film and so on. Liquid insulating materials are mainly mineral insulating oil, synthetic ...
2017 - 12 - 05
development of the construction industry views" (hereinafter referred to as No. 19), third of which clearly put forward to accelerate the implementation of the development of EPC in perfect engineering construction organization mode.As a general contracting the development of electric power industry experience, advocate, recently, deputy general manager, Chinese Power Construction Group China...
Address:No. 1, Guang long Zhong Road, Guangzhou Long Industrial District, Chen Cun town, Shunde District, Foshan, Guangdong Province, China
Tel:0757-23810755;23810855;23810955
Fax:0757-23810255 MR.Huang 13926406303;MR.Yin 13922728266
Zip code:330520
Copyright ©2017 - 2022Foshan Xingya Rui insulation products Co. Ltd.
犀牛云提供企业云服务
 
X
1

QQ设置

3

SKYPE 设置

4

阿里旺旺设置

5

电话号码管理

  • 0757-23810755
6

二维码管理

Open